13.3

Drill hose

 

1 set

 

 

 

13.3.1

Version according to the standard, specifications

API Spec 7K

 

 

 

 

13.3.2

Operating pressure, at least

35.0 MPa (5000 psi)

 




 

 

13.3.3

Drift diameter

101.6 mm (4'')

 




 

 

13.3.4

Length

25 m (82 feet)

 

 

 

 

13.4

Cementing manifold

 

1 set

 

 

 

13.4.1

Operating pressure, at least

70,0 MPa (10000 psi)

 




 

 

13.4.2

Diameter

89 mm (OD 3'')

 

 

 

 

14

Low pressure mud system (circulation system)

 

1 set

 

 

 

14.1

Version according to the standard, specifications

 API 13C

 

 

 

 

14.1.1

Total capacity of mud tanks, at least

360 m3

 

 

 

 

14.1.2

Total number of mud tanks

 

6 sets

 

 

 

 

Mud cleaning tank, capacity at least

45 m3

1 set

 

 

 

 

Intermediate tank, capacity at least

70 m3

1 set

 

 

 

 

Receiving tanks, capacity at least

70 m3

3 sets

 

 

 

 

Mud mix system, capacity at least

35 m3

1 set

 

 

 

14.1.3

Auxiliary tanks

 

 

 

 

 

 

Additional receiving tank, capacity at least

30 m3

1 set

 

 

 

 

Water tank, capacity at least

50 m3

1 set

 

 

 

14.1.4

Service lines

All tanks are fitted with all necessary pipelines for connection to the circulation system, mud cleaning system, refilling system and mud mixing unit

 

 

 

 

14.1.5

Seals

Oil resistant.

 

 

 

 

14.1.6

Allowable mud density, at least

2200 kg/m3

 

 

 

 

14.2

Mud cleaning tank,

capacity at least

45 m3

1 set

 

 

 

14.2.1

The design includes:

 

 

 

 

 

 

Mud pit No. 1 mud settling pit (sloping wall) , capacity at least

10 m3

 

 

 

 

 

Mud pit No. 2 for desander (sloping wall) , capacity at least

17 m3

 

 

 

 

 

Mud pit No. 3 for desander (sloping wall) , capacity at least

18 m3

 

 

 

 

 

Mud ditch from shakers to mud settling pit

 

 

 

 

 

 

Mud ditch from settling pit to mud pits of additional receiving tank with adjustable slide dampers

 

 

 

 

 

 

Place for the shale shaker (including header box)

 

4 places

 

 

 

 

Place for one desander pump

 

1 place

 

 

 

 

Place for desilter pump

 

1 place

 

 

 

 

Place for high pressure washer

 

1 place

 

 

 

 

Service lines

The piping of mud cleaning system must provide multistage mud cleaning. The tank must be fitted with hatches for tank cleaning. The piping of mud cleaner and transfer pumps must provide ability of mud transfer from / between mud pits #2, #3 and mud pit #1 of additional receiving tank.

 

 

 

 

14.3

Additional receiving tank, capacity at least

30 m3

1 set

 

 

 

14.3.1

The design includes:

 

 

 

 

 

 

Mud pit No. 1 for desilter (sloping wall) , capacity at least

15 m3

 

 

 

 

 

Mud pit No. 2 for degagger (sloping wall) , capacity at least

15 m3

 

 

 

 

 

Ditch from mud cleaner to desilter pit (Mud pit No.1) and to the main ditch

 

 

 

 

 

 

Mud ditch from additional receiving tank to intermediate tank with adjustable slide dampers

 

 

 

 

 

 

Place for mud cleaner

 

1 ea

 

 

 

 

Place for Degasser

 

1 ea

 

 

 

 

Place for the centrifuge

 

1 ea

 

 

 

 

Place for the agitator

 

1 ea

 

 

 

 

Service lines

Each tank must be fitted with all necessary pipelines for connection with the circulation system. The tank must be fitted with hatches for tank cleaning

 

 

 

 

14.4

Intermediate tank, capacity at least

70 m3

1 set

 

 

 

14.4.1

The design includes:

 

 

 

 

 

 

Mud pit No. 1, capacity at least

35 m3

 

 

 

 

 

Mud pit No. 2, capacity at least

35 m3

 

 

 

 

 

Mud ditch from the intermediate tank to receiving tank with adjustable slide dampers

 

 

 

 

 

 

Place for the centrifuge

 

1 place

 

 

 

 

Place for the agitator

 

2 places

 

 

 

 

Service lines

The tank must be fitted with all necessary pipelines for connection with the circulation system. The tank must be fitted with hatches for tank cleaning

 

 

 

 
1   ...   5   6   7   8   9   10   11   12   ...   30

Схожі:

Public joint stock company "ukrgasvydobuvannia"

Public joint stock company "ukrgasvydobuvannia"

Public joint stock company "ukrgasvydobuvannia"

Public joint stock company "ukrgasvydobuvannia"

Public joint stock company "ukrgasvydobuvannia"

Agreement with the member of the supervisory board of public joint-stock...
Договір з членом наглядової ради публічного акціонерного товариства "страхова компанія "євроінс україна"

To: Public Joint Stock Company “Kreditprombank”, 38, Boulevard Druzhby...
Публічне акціонерне товариство «Кредитпромбанк» 38, бульвар Дружби народів, 01014 м. Київ, Україна

Public Joint Stock Company «Ukrgasvydobuvannya»
«Ukrgasvydobuvannya», represented by commercial director Sergey Fedorenko, acting on the basis of the Power of Attorney №2-406d dated...



База даних захищена авторським правом © 2020
звернутися до адміністрації




blanki-ua.com.ua


Головна сторінка

Бланки резюме
Бланк довіреності
Бланк заяв
Заява зразок
Договір розірвання
Зразок позовної заяви
Заява на паспорт